SINTOFOIL ST

Non-reinforced TPO/FPA membrane for single ply waterproofing of exposed flat roofs bonded on the lower face with nonwoven polyester fabric.

Synthetic waterproofing membrane produced by co-extruding a uniform UV resistant elastomerised TPO/FPA thermoplastic olefin and flexible polypropylene alloy. The membrane features contrasting colours on its upper and lower faces, providing a signal layer so that any damage occurring during or after installation will be immediately apparent. SINTOFOIL ST membranes comply with CE marking requirements, if applicable..

Fields of application

Specific use

  • Waterproofing layers applied independently under heavy-duty fixed or movable protection for:

    - roofing exposed to foot traffic and roof gardens.

  • Mechanically retained waterproofing on exposed roofs.

TECHNICAL FEATURES (1)

Features EN Standards U.M. Tolerance Values
Standard thickness 1849-2 mm (-5/+10%) 1,2 1,5 1,8 2,0
Tensile properties
Tensile strength L/T 12311-2 N/mm² 16 / 15
Elongation at break L/T 12311-2 % 700 / 700
Dimensional stability 1107-2 % ≤ 0.5
Cold flexibility 495/5 °C ≤ -40 (2)
Tear resistance L/T 12310/1 N 330 / 240 450 / 400 550 / 500 650 / 600
Water vapour permeability (resistance factor μ) 1931 90.000
Resistance to static loading 12730/B kg ≥ 25
Resistance to impact 12691/B mm ≥ 1000
Hail resistance 13583 m/s ≥ 30 (3)
Water tightness (60 kPa) 1928 Absolute
Joint strength
Tensile strength 12317-2 N/cm Compliant (specimen fails outside bond area)
Peeling 12316-2 N/cm ≥ 58
Durability
Resistance to artificial UV light 1297-5000 h No surface damage or significant changes in cold flexibility as per EN 495/5
Heat aging in area
Change in tensile strength 12311-2 Δ% -5
Change in elongation at break 12311-2 Δ% -5
Reaction to fire 13501-1 Class E
Resistance to algae and microorganisms ISO 846 Level 2 Compliant
Root resistance 13948 Passes the test
Contact with drinking water (DW) Italian Ministerial Decree 26-04-93 n. 220 - O.J. no. 162 / 13-07-1993 and subsequent amendments Suitablet

Notes:

(1) Tolerances as per EN 13956 and/or UEAtc Directives.
(2) Not tested at lower temperatures.
(3) Not tested at higher speeds.

PRODUCTION STANDARDS

Thickness (*) mm 1,2 1,5 1,8 2,0
Width m 2,10 2,10 2,10 2,10
Length (*) m 25 25 20 20
Standard colour (*) Grey / Black

(*) Different thicknesses, lengths and colours are available on demand and for minimum quantities