SINTOFOIL RG
Fiberglass reinforced TPO/FPA membrane for single ply waterproofing of exposed flat roofs.
Synthetic waterproofing membrane produced by co-extruding a UV resistant elastomerised TPO/FPA thermoplastic olefin and flexible polypropylene alloy with a fibreglass reinforcing mat that makes it dimensionally stable. The membrane features contrasting colours on its upper and lower faces, providing a signal layer so that any damage occurring during or after installation will be immediately apparent. Available in BIANCO REFLECTA version, manufactured with the upper side of the membrane (top) in WHITE REFLECTA colour, by means of a treatment developed in mass in the entire layer that covers the top of the reinforcement. This process enhances the reflectance and emission features giving the roof a Solar Reflectance Index (SRI) value that reach 102%. Also available in the fire resistant versions (external fire behaviour), in Broof class according to EN 13501-5: SINTOFOIL RG/FR1(1), SINTOFOIL RG/FR2(2), SINTOFOIL RG/FR3(3), SINTOFOIL RG/FR4(4) (consult the specific data sheet - SINTOFOIL RG/FR). SINTOFOIL RG membranes comply with CE marking requirements, if applicable.
Notes:
(1) Sintofoil RG/FR1 – Behaviour to external fire (ENV 13501-5) Broof (t1).
(2) Sintofoil RG/FR2 – Behaviour to external fire (ENV 13501-5) Broof (t2).
(3) Sintofoil RG/FR3 – Behaviour to external fire (ENV 13501-5) Broof (t3).
(4) Sintofoil RG/FR4 – Behaviour to external fire (ENV 13501-5) Broof (t4).
Fields of application
Specific use
- Waterproofing layers applied independently under heavy-duty fixed or movable protection for:
- roofing exposed to foot traffic;
- roof gardens. - Mechanically retained waterproofing for:
- exposed roofs.
TECHNICAL FEATURES (1)
Features | EN Standards | U.M. | Tolerance | Values | |||
---|---|---|---|---|---|---|---|
Standard thickness | 1849-2 | mm | (-5/+10%) | 1,2 | 1,5 | 1,8 | 2,0 |
SRI – Solar Reflectance Index | ASTM Stardard E1980 | % | 102 (2) | ||||
Tensile properties | |||||||
Tensile strength L/T | 12311-2 | N/50 mm | 600 / 550 | 650 / 600 | 750 / 750 | 800 / 800 | |
Elongation at break L/T | 12311-2 | % | 700 / 700 | ||||
Dimensional stability | 1107-2 | % | ≤ 0.1 | ||||
Cold flexibility | 495/5 | °C | ≤ -40 (3) | ||||
Tear resistance L/T | 12310/1 | N | 390 / 290 | 450 / 400 | 500 / 450 | 600 / 550 | |
Water vapour permeability (resistance factor μ) | 1931 | 50.000 | |||||
Resistance to static loading | 12730/B | kg | ≥ 25 | ||||
Resistance to impact | 12691/B | mm | ≥ 1000 | ||||
Hail resistance | 13583 | m/s | ≥ 30 (4) | ||||
Water tightness (60 kPa) | 1928 | Absolute | |||||
Joint strength | |||||||
Tensile strength | 12317-2 | N/cm | Compliant (specimen fails outside bond area) | ||||
Peeling | 12316-2 | N/cm | ≥ 58 | ||||
Durability | |||||||
Resistance to artificial UV light | 1297-5000 h | No surface damage or significant changes in cold flexibility as per EN 495/5 | |||||
Heat aging in area | |||||||
Change in tensile strength | 12311-2 | Δ% | -5 | ||||
Change in elongation at break | 12311-2 | Δ% | -5 | ||||
Reaction to fire | 13501-1 | Class E | |||||
Behaviour to external fire | 13501-5 | Froof (5) | |||||
Resistance to algae and microorganisms | ISO 846 Level 2 | Compliant | |||||
Root resistance | 13948 | Passes the test |
Notes:
(1) Tolerances as per EN 13956 and/or UEAtc Directives.
(2) Reflecta White version.
(3) Not tested at lower temperatures.
(4) Not tested at higher speeds.
(5) Also available in the fire resistant versions (external fire behaviour), in Broof class according to EN 13501-5: SINTOFOIL RG/FR1, SINTOFOIL RG/FR2, SINTOFOIL RG/FR3, SINTOFOIL RG/FR4 (consult the specific data sheet - SINTOFOIL RG/FR).
PRODUCTION STANDARDS
Thickness (*) | mm | 1,2 | 1,5 | 1,8 | 2,0 |
Width | m | 2,10 | 2,10 | 2,10 | 2,10 |
Length (*) | m | 25 | 25 | 20 | 20 |
Standard colour (*) | Grey / Black |
(*) Different thicknesses, lengths and colours are available on demand and for minimum quantities