LOGICROOF P-RP FB

Polyester reinforced TPO/FPA membrane for single ply waterproofing of exposed flat roofs bonded on the lower face with nonwoven polyester fabric

Synthetic waterproofing membrane produced by co-extruding a UV resistant elastomerised TPO/FPA thermoplastic olefin and flexible polypropylene alloy with a polyester net reinforcing mat bonded on the lower face with nonwoven polyester fabric. The membrane features contrasting colors on its upper and lower faces, providing a signal layer so that any damage occurring during or after installation will be immediately apparent.

Available in the BIANCO REFLECTA version, manufactured with the upper side of the membrane in WHITE REFLECTA color. This enhances the reflectance and emission features, giving the roof a Solar Reflectance Index (SRI) value that reaches 102%.

Fields of application

  • Waterproofing of flat roofs in adhered roof systems.
  • Waterproofing layers applied independently under heavy-duty fixed or movable protection: roofing exposed to foot traffic; inverted roofs.

TECHNICAL FEATURES (1)

Features EN Standards U.M. Tolerance Values
Standard thickness 1849-2 mm (-5/+10%) 1,2 1,5 1,8 2,0
Tensile strength L/T 12311-2 N/50 mm 1100 / 1100
Elongation at break L/T 12311-2 % 25 / 25
Dimensional stability 1107-2 % ≤ 0.5 / 0.5
Cold flexibility 495/5 °C ≤ -40 (2)
Tear resistance L/T 12310/1 N 550 / 650 (*)
Water vapour permeability (resistance factor μ) 1931 50.000
Resistance to static loading 12730/B kg ≥ 25 (*)
Resistance to impact 12691/B mm ≥ 1800 (*)
Hail resistance 13583 m/s ≥ 30 (3)
Water tightness (60 kPa) 1928 Absolute
Joint strength
Tensile strength 12317-2 N/cm Compliant (specimen fails outside bond area)
Peeling 12316-2 N/cm ≥ 58
Resistance to artificial UV light 1297-5000 h No surface damage or significant changes in cold flexibility as per EN 495/5
Heat aging in area
Change in tensile strength 12311-2 Δ% -5
Change in elongation at break 12311-2 Δ% -5
Reaction to fire 13501-1 Class F
Resistance to algae and microorganisms ISO 846 Level 2 Compliant
Root resistance 13948 Passes the test

Notes:

(1) Tolerances as per EN 13956 and/or UEAtc Directives.
(*) The values indicated refer to the TPO / FPA membrane without nonwoven polyester fabric backing, except for the values marked with an asterisk (*), that refer to the finished product.
(2) Not tested at lower temperatures.
(3) Not tested at higher speeds

PRODUCTION STANDARDS

Thickness (*) mm 1,2 1,5 1,8 2,0
Width m 2,10 2,10 2,10 2,10
Length (*) m 25 25 20 20
Standard colour (*) Grey / Black

(*) Different thicknesses, lengths and colours are available on demand and for minimum quantities