Synthetic waterproofing membrane produced by co-extruding a UV resistant elastomerised TPO/FPA thermoplastic olefin and flexible polypropylene alloy with a fiberglass reinforcing mat bonded on the lower face with nonwoven polyester fabric. The membrane features contrasting colors on its upper and lower faces, providing a signal layer so that any damage occurring during or after installation will be immediately apparent.

Available in BIANCO REFLECTA version, manufactured with the upper side of the membrane in WHITE REFLECTA color. This enhances the reflectance and emission features giving the roof a Solar Reflectance Index (SRI) value that reach 102%.

Fields of application

  • Waterproofing of flat roofs in adhered roof systems.
  • Waterproofing layers applied independently under heavy-duty fixed or movable protection for: roofing exposed to foot and vehicular traffic; roof gardens.

TECHNICAL FEATURES (1)

Features EN Standards U.M. Tolerance Values
Standard thickness 1849-2 mm (-5/+10%) 1,2 1,5 1,8 2,0
Tensile properties
Tensile strength L/T 12311-2 N/50 mm 600 / 550 650 / 600 750 / 750 800 / 800
Elongation at break L/T 12311-2 % 700 / 700
Dimensional stability 1107-2 % ≤ 0.1
Cold flexibility 495/5 °C ≤ -40 (2)
Tear resistance L/T 12310/1 N 500 / 450 (*) 650 / 600 (*) 750 / 700 (*) 850 / 800 (*)
Water vapour permeability (resistance factor μ) 1931 50.000
Resistance to static loading 12730/B kg ≥ 25
Resistance to impact 12691/B mm ≥ 1000
Hail resistance 13583 m/s ≥ 30 (4)
Water tightness (60 kPa) 1928 Absolute
Joint strength
Tensile strength 12317-2 N/cm Compliant (specimen fails outside bond area)
Peeling 12316-2 N/cm ≥ 58
Durability
Resistance to artificial UV light 1297-5000 h No surface damage or significant changes in cold flexibility as per EN 495/5
Reaction to fire 13501-1 Class E
Resistance to algae and microorganisms ISO 846 Level 2 Compliant
Root resistance 13948 Passes the test

Notes:

(1) Tolerances as per EN 13956 and/or UEAtc Directives.
(*) The values indicated refer to the TPO / FPA membrane without nonwoven polyester fabric backing, except for the values marked with an asterisk (*), that refer to the finished product.
(2) Not tested at lower temperatures.
(3) Not tested at higher speeds.

PRODUCTION STANDARDS

Thickness (*) mm 1,2 1,5 1,8 2,0
Width m 2,10 2,10 2,10 2,10
Length (*) m 25 25 20 20
Standard colour (*) Grey / Black

(*) Different thicknesses, lengths and colours are available on demand and for minimum quantities